• Register
  • Login

Iranian Journal of Pharmaceutical Sciences

  • Home
  • Journal Info
    • About the Journal
    • Aims and Scope
    • Editorial Team
    • Indexing & Abstracting
    • Privacy Statement
    • Contact us
  • Issues
    • Current
    • Archives
  • New Submissions
  • Author Guidelines
  • Policies & Process
    • Peer Review
    • Publication Ethics
    • Open Access Policy
    • Plagiarism
    • Retraction Policies
    • Archiving
  • Ethical Considration
Advanced Search
  1. Home
  2. Archives
  3. Vol. 4 No. 1 (2008): IJPS_Volume 4_Issue 1 (2008)
  4. Research/Original Articles

Vol. 4 No. 1 (2008)

January 2008

Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles Bone tissue response to hydroxyapatite-coated Ti-6Al-4V substrates

  • Aliasghar Behnamghader
  • Davood Sharifi
  • Sarang Soroori
  • Narjes Bagheri
  • Ranna Tolouei
  • Roghieh Nemati
  • Denis Najjar
  • Alain Iost

Iranian Journal of Pharmaceutical Sciences, Vol. 4 No. 1 (2008), 15 January 2008 , Page 57-62
https://doi.org/10.22037/ijps.v4.39817

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

In this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. A well-known porous and lamellar microstructure was found in the lateral and outer surface of coating. The phase composition was studied by XRD and the morphological and the microstructural aspects were investigated by scanning electron and optical microscopy. The hardness of coatings and substrates was measured by Vickers indentation method. For in vivo study, rabbit condyles were exposed to two groups of coated and uncoated samples. Radiographyically, different parameters such as bone lysis, sclerosis, displacement of samples and bone resorption were taken into consideration and no statistically differences between the two groups, with no sign of infection on the edges of each hole were found. Histopathological interpretation of all coated samples indicated that the extent of callus and thickness of speculae were quite distinct from that of uncoated group. In this group, the space between implant and canal was filled up with matured connective tissues and plenty of bone speculae of woven bone in nature. However, these speculaes were thinner and immature as compared to coated samples.

Keywords:
  • Hydrxyapatite coating
  • Implants
  • Plasma spraying
  • IJPS_Volume 4_Issue 1_Pages 57-62

How to Cite

Behnamghader, A. ., Sharifi, D. ., Soroori, S. ., Bagheri, N. ., Tolouei, R., Nemati, R. ., … Iost, A. . (2008). Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles: Bone tissue response to hydroxyapatite-coated Ti-6Al-4V substrates. Iranian Journal of Pharmaceutical Sciences, 4(1), 57–62. https://doi.org/10.22037/ijps.v4.39817
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

[1] Burser D, Schenk RK, Steinmann S, Fiorelini JP, Fox C, Stich H. Influence of surface characteristics on bone integration of Titanium implants: A histomorphometric study in miniature pigs. J Biomed Mater Res 1991; 25: 889-90.
[2] Rimondini L, Rondelli G, Quirici N. In vitro corrosion characterization and cell proliferation on surface modified titanium. Material Wiss 2002; 33: 716-9.
[3] Ducheyne P, Cuckler JM. Bioactive ceramic prosthetic coatings. Clin Orthop Rel Res 1992; 276: 102-14.
[4] Wennerberg A, Albrektsson T, Johansson C, Andersson B. Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topography. Biomaterials 1996; 17: 15-21.
[5] Park JH, Lee YK. Bioactive calcium phosphate coating prepared on H2O2- treated titanium substrate by electro deposition. Surf Coat Tech 2005; 195: 252-7.
[6] Wen HB, Liu Q. Preparation of bioactive microporous titanium surface by a new two-step chemical treatment. J Mater Sci 1998; 9: 121-8.
[7] Liang F. Apatite formation on titanium by alkali and heat treatment. Surf Technol 2003; 165: 133-9.
[8] Vanzillotta PS, Sader MS. Improvement of in vitro titanium bioactivity by three different surface treatments. Dent Mater 2006; 22: 275-82.
[9] Jaffe WL, Scott DF. Current concepts review: Total hip arthroplasty with hydroxyapatite-coated prostheses. J Bone Jt Surg 1996; 78A: 1918-34.
[10] Yang Y, Kim KH, Ong JL. A review on calcium phosphate coatings produced using a sputtering process-an alternative to plasma spraying. Biomaterials 2005; 26: 327-37.
[11] Sun L. Materials fundamental and clinical performance of plasma-sprayed hydroxyapatite mcoatings. J Biomed Mater Res 2001; 58: 570-92.
[12] Herman H. Plasma spray deposition processes. MRS Bull 1988; 12: 60-7.
[13] Luna LG. Manual of histologic staining method of the Armed Forces Institute of Pathology. 3rd ed., Mc Graw- Hill Company. 1968; pp. 32-46, pp. 94-5.
[14] Thomas KA. Hydroxyapatite coatings. Orthopedics 1994; 17: 267-78.
[15] D'Antonio JA, Capello WN, Manley MT, Feinberg J. Hydroxyaptite coated implants. Clin Orthp Relat Res 1997; 344:124-38.
[16] Filiaggi MJ, Coombs NA, Pilliar RM. Characterization of the interface in the plasma-sprayed HAcoating/Ti-6Al-4V implant system. J Biomed Mater Res 1991; 25: 1211-29.
[17] Chen J, Wolke JGC, deGroot K. Microstructure and crystallinity in hydroxyapatite coatings. Biomaterials 1994; 15: 396-9.
[18] Bull SJ, Rickerby DS. New development in the modeling of the hardness and scratch adhesion of thin films. Br Ceram Trans 1989; 88: 177-83.
[19] Fawcett DW. Bloom and Fawcett: A textbook of histology. 12th ed. New York: Chpman and Hall, 1994.
[20] Lee JH, Ryu HS, Lee DS, Hong KS, Chang BS, Lee CK. Biomechanical and histomorphometric study on the bone-screw interface of bioactive ceramic-coated titanium screws. Biomaterials 2005; 26: 3249-57.
[21] Moroni A, Toksvig-Larsen S, Maltarello MC. A comparison of hydroxyapatite-coated, titaniumcoated, and uncoated tapered external-fixation pins. J Bone Joint Surg 1998; 80: 547-54.
  • Abstract Viewed: 291 times
  • IJPS_Volume 4_Issue 1_Pages 57-62 Downloaded: 161 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Creative Commons License
This journal (and its contents) is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Print ISSN: 1735-2444

Online ISSN: 2252-0457

Powered by OJSPlus