• Register
  • Login

Iranian Journal of Pharmaceutical Sciences

  • Home
  • Journal Info
    • About the Journal
    • Aims and Scope
    • Editorial Team
    • Indexing & Abstracting
    • Privacy Statement
    • Contact us
  • Issues
    • Current
    • Archives
  • New Submissions
  • Author Guidelines
  • Policies & Process
    • Peer Review
    • Publication Ethics
    • Open Access Policy
    • Plagiarism
    • Retraction Policies
    • Archiving
  • Ethical Considration
Advanced Search
  1. Home
  2. Archives
  3. Vol. 4 No. 1 (2008): IJPS_Volume 4_Issue 1 (2008)
  4. Research/Original Articles

Vol. 4 No. 1 (2008)

January 2008

Electrophoretic Deposition of Hydroxyapatite Electrophoretic deposition of hydroxyapatite

  • Aliasghar Behnamghader
  • Narjes Bagheri
  • Babak Raissi
  • Tahmineh Forati
  • Dionysia Ntentopoulou
  • Ehsan Marzbanrad

Iranian Journal of Pharmaceutical Sciences, Vol. 4 No. 1 (2008), 15 January 2008 , Page 63-68
https://doi.org/10.22037/ijps.v4.39820

  • View Article
  • Download
  • Cite
  • References
  • Statastics
  • Share

Abstract

The purpose of this study was to investigate the deposition of the hydroxyapatite(HA) coating via the electrophoresis procedure. The HAdeposition was performedin an ethanol, methanol, acetone and isopropanol suspension. Methanol was foundto be the best deposition media. Among the different environmental conditions,including the encapsulation of the samples under two vacuum types of pressure(10-5-10-4and 2×10-2Torr) and also thepurge of the argon gas in the tube-likefurnace, the optimum environment was the one demonstrating the encapsulation underthe vacuum pressure of 2×10-2Torr (washing with argon gas of 99.9% purity). Afterthe examination of 3 sintering temperatures (1020, 1050 and 1100 ºC), the sinteringtemperature at 1050 ºC illustrated the most desired results. The samples sintered underthese conditions were apparently intact, most of the interfacial part of the coatingwas found to be attached to the substrate surface irregularities and no single crackswere observed.

Keywords:
  • Coating
  • Electrophoretic deposition
  • Hydroxyapatite
  • Sintering
  • IJPS_Volume 4_Issue 1_Pages 63-68

How to Cite

Behnamghader, A. ., Bagheri, N. ., Raissi, B. ., Forati, T. ., Ntentopoulou, D. ., & Marzbanrad, E. . (2008). Electrophoretic Deposition of Hydroxyapatite: Electrophoretic deposition of hydroxyapatite. Iranian Journal of Pharmaceutical Sciences, 4(1), 63–68. https://doi.org/10.22037/ijps.v4.39820
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

[1]LeGeros RZ, LeGeros JP. An introduction tobioceramics, Dense hydroxyapatite. In: HenchLL, Wilson J, (editor). Advanced Series inCeramics. Boca Raton: World Scientific, 1993; pp.139-80.
[2]Tsui YC, Doyle C, Clyne TW. Plasma sprayedhydroxyapatite coatings on titanium substrates.Part 2: Optimization of coating properties.Biomaterials1998; 19: 2031-43.
[3]Behnamghader A. Mechanical properties ofsurfaces and interfaces-application in articular prostheses. PhD Thesis, ENSAM, France, 1999.
[4]Khor KA, Cheang P, Wang Y. The thermal sprayprocessing of HApowders and coatings. J Met1997; 49: 51-7.
[5]Sarkar P, Nicholson PS. Electrophoretic deposition(EPD): Mechanisms, kinetics, and application toceramics. J Am Ceram Soc1996; 79: 1987-2002.
[6]Faires LM. Inductively coupled plasma-atomicemission spectroscopy. In: Ruth E, (Coordinator)ASM Handbook Committee. Materials Charac-terization. New Yourk: ASM InternationalPublishing Co. 1992; 10: 31-42.
[7]Zhitomirsky I. Cathodic electrodeposition ofceramic and organoceramic materials-Fundamental aspects. Adv Colloid Interfac 2002;97: 279-317.
[8]Zhitomirsky I, Gal-Or L. Electrophoreticdeposition of hydroxyapatite. J Mater Sci MateM1997; 8: 213-9.
[9]Ducheyne P, Radin S. Calcium phospate ceramiccoatings on porous titanium: effect of structure andcomposition on electrophoretic deposition,vacuum sintering and in vitrodissolution.Biomaterials1990; 11: 244-54.
[10]Stoch A, Brozek A, Kmita G, Stoch J, JastrzebskiW, Rakowska A. Electrophoretic coating ofhydroxyapatite on titanium implants. J Mol Struct2001; 596: 191-200.[11]Agata de sena L, Calixto de Andrade M, RossiAM, Gloria de Almeida S. Hydroxyapatitedeposition by electrophoresis on titanium sheetswith different surface finishing. J Biomed MaterRes2002; 60: 1-7.
[12]Bohner M. Calcium orthophosphates in medicine:From ceramics to calcium phosphate cements.Injury2000; 31: 37-47.
[13]Wei M. Electrophoretic deposition ofhydroxyapatite coatings on metal substrates: Ananoparticulate dual-coating approach. J Sol-GelSci Technol2001; 21: 39-48.
[14]Wang PE, Chaki TK. Sintering behaviour andmechanical properties of hydroxyapatite anddicalcium phosphate. J Mater Sci Mate M 1993;4: 150-8.
[15]Weng J. Thermal decomposition of hydroxyapatitestructure induced by titanium and its dioxide. JMater Sci Lett 1994; 13: 159-61.
  • Abstract Viewed: 256 times
  • IJPS_Volume 4_Issue 1_Pages 63-68 Downloaded: 208 times

Download Statastics

  • Linkedin
  • Twitter
  • Facebook
  • Google Plus
  • Telegram

Developed By

Open Journal Systems

Information

  • For Readers
  • For Authors
  • For Librarians
  • Home
  • Archives
  • Submissions
  • About the Journal
  • Editorial Team
  • Contact

Creative Commons License
This journal (and its contents) is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Print ISSN: 1735-2444

Online ISSN: 2252-0457

Powered by OJSPlus